24/7 Emergency Response +55 11 99499-4141
Corvaden

Steel renewal is priced on tonnage and won or lost on access. The plate itself is rarely the difficulty. Staging, gas-freeing, ventilation, and getting material and crew to the frame that actually needs cutting is where the time goes, and it is the part most quotations describe least.

Corvaden surveys before quoting, and quotes against a defined tonnage and a defined set of members. Where survey opens up wastage beyond that boundary it is reported, priced and agreed before it is cut — not added to the final account afterwards. The inclusions and exclusions that apply to every quotation are published rather than kept in the small print.

Work is executed afloat wherever the structure and the class requirement allow it, and in dock where they do not.

Capabilities

Structure

  • Transverse and longitudinal bulkheads
  • Shell and bottom plating
  • Frames, stiffeners, brackets and face plates
  • Tank top and double bottom
  • Deck plating, hatch covers and coamings

Execution

  • Crop and renew
  • Insert plates
  • Doublers where class permits
  • Staging, access and ventilation
  • Gas-freeing and permit control before hot work

Welding and testing

  • Welding to approved procedure specifications
  • Qualified welders
  • Visual and ultrasonic testing
  • Magnetic particle and dye penetrant testing
  • Hydrostatic and air testing of renewed boundaries

Reinstatement

  • Surface preparation within worked areas
  • Coating reinstatement to the owner's specification
  • Anodes and fittings refitted as found

Indicative manning and duration

A reference table, not a quotation. It opens on the 20 MT AH36 baseline drawn from a real Corvaden job and revises against a tonnage, a mode and a scope type. It states crew and duration only — a price requires a survey.

Alongside or at anchorage. Staging, ventilation and permit control govern the programme.

Indicative crew composition and duration for 20 tonnes, afloat, bulkheads and shell plating
CompositionNo.
Project engineer1
Repair foreman1
Certified welders8
Steel fitters5
Safety officers2
Riggers and helpersAs required
Quantified personnel17
Indicative duration
10–14 days
Mobilisation
48 hours

20 tonnes, afloat, bulkheads and shell plating: 17 personnel plus riggers as required, indicative duration 10 to 14 days. Indicative only. Subject to survey and confirmed scope.

Indicative only. Subject to survey and confirmed scope.

Send this scope for survey

To be confirmed

  • Welder qualification standard and the approving society

Response in 6 hours. Mobilisation in 48 hours.

Send the repair specification, the class report and photographs with the first enquiry. Scope confirmed against documents is scope that does not change on arrival.

Response
6 h
Mobilisation
48 h